KD-O505F Oxygen Concentrator
  • KD-O505F Oxygen Concentrator
  • KD-O505F Oxygen Concentrator
  • KD-O505F Oxygen Concentrator
  • KD-O505F Oxygen Concentrator
KD-O505F Oxygen Concentrator
Product Advantages
1. Humidifier bottle: SALTER LAB from America. Its pressure release can be up to 6PSI(0.041MPa),other brand humidifier pressure release is 3PSI, which will made patient feel more comfortable when inhale oxygen;
 2.Inner case housing adopt Ceramics technique,non spray paint;
 3. Customerized mute cotton make sure non pulverization phenomenon min 3 years;
 4. The machine inside pipeline use the Medical class silicone tube and nylon tube, more safe than industrial silicone tube and plastic tube, no pollution, no peculiar smell;     
 5. Molecular sieve seal ring adopt medical silicon rubber material;And the molecular sieve tank is very firm, which cover is fixed by the screw to avoid the phenomenon of spray zeolite;
 6.  Cooling system: copper tube and  aluminum fins, compare with only aluminum or copper tube better for heat dissipation and ensure the machine to continuously work for 24 hours without overheat interruption
 7.  With pressure sensor, it can be used in highland, and make sure the abundant oxygen;

Features:

Flow Rate 0-5L/min
Purity 93±3%
Outlet Pressure (Mpa) 0.04-0.07
Sound Level ≤50db
Power AC220V±10%, 50/60±1Hz; AC110V±10%, 50/60±1Hz
Power Consumption ≤550W
Timer Present Working Time, Accumulating Time, Presetting Time from 10mins to 40hours
Alarm Power failure alarm, High&Low pressure alarm
Net Weight 26Kgs
Size (mm) 365×375×600mm
Optional:
*Nebulizer
*Low purity alarm: when oxygen purity is above 82%, it will give green light; when the purity is blow 82%( 82% not included), it will give red light
*Maintenance alarm: alarm for maintenance after 3000 hours operation
*Alarm for high temperature inside systems above 50 degree.
*Pulse oximeter: fingertip pulse oximeter is available for monitoring patient oxygen saturation on site.
*Small LCD display: accumulating time; present working time presetting time.                                  